Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Journal of the Korean Radiological Society ; : 808-829, 2022.
Article in English | WPRIM | ID: wpr-938380

ABSTRACT

Hepatocellular carcinoma (HCC) can be diagnosed noninvasively on multiphasic CT and MRI based on its distinctive imaging findings. These features include arterial phase hyperenhancement and washout on portal or delayed phase images. However, radiologists face significant diagnostic challenges because some HCCs exhibit atypical imaging characteristics. In addition to many HCC-mimicking lesions, such as arterioportal shunts, combined HCC-cholangiocarcinoma, intrahepatic cholangiocarcinoma, and hemangioma present a challenge for radiologists in actual clinical practice. The ability to distinguish HCCs from mimickers on initial imaging examinations is crucial for appropriate management and treatment decisions. Therefore, this pictorial review presents the imaging findings of atypical HCCs and HCCs mimicking malignant and benign lesions and discusses important clues that may help narrow down the differential diagnosis.

2.
Journal of the Korean Radiological Society ; : 608-619, 2022.
Article in English | WPRIM | ID: wpr-926450

ABSTRACT

Purpose@#This study aimed to evaluate the natural growth of subepithelial tumors of the small bowel detected on CT. @*Materials and Methods@#Consecutive patients who were suspected of having subepithelial tumors of the small bowel between January 2005 and December 2020 were reviewed. Eligible patients with suspected small (< 30 mm) subepithelial tumors on at least two CT evaluations were included in the analysis. The patients’ data on demographic characteristics, tumoral characteristics, and tumoral size changes during the follow-up were collected. @*Results@#This study included 64 patients with suspected small subepithelial tumors (n = 64) of the small bowel. After a median follow-up of 15.8 months, the diameter and volume growth rates were 0.02 mm/month and 1.5 mm3/month, respectively. A significant correlation was observed between the initial size and the growth rate of the small bowel subepithelial tumors. The group of large-sized tumors (initial diameter ≥ 10 mm) tended to show lobulated contours, heterogeneous enhancement, and necrotic changes more frequently than the group of small-sized tumors (initial diameter < 10 mm). @*Conclusion@#Small bowel subepithelial tumors measuring less than 10 mm grew more slowly than those measuring 10–30 mm.

3.
Korean Journal of Radiology ; : 1066-1076, 2021.
Article in English | WPRIM | ID: wpr-902449

ABSTRACT

Objective@#To evaluate the performance of the 2018 Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) Practice Guidelines (hereafter, PG) for the diagnosis of hepatocellular carcinoma (HCC) using gadoxetic acid-enhanced MRI, compared to the Liver Imaging-Reporting and Data System (LI-RADS) version 2018 (hereafter, v2018). @*Materials and Methods@#From January 2013 to October 2015, treatment-naïve hepatic lesions (≥ 1 cm) on gadoxetic acidenhanced MRI in consecutive patients with chronic hepatitis B or cirrhosis were retrospectively evaluated. For each lesion, three radiologists independently analyzed the imaging features and classified the lesions into categories according to the 2018 KLCA-NCC PG and LI-RADS v2018. The imaging features and categories were determined by consensus. Generalized estimating equation (GEE) models were used to compare the per-lesion diagnostic performance of the 2018 KLCA-NCC PG and LI-RADS v2018 using the consensus data. @*Results@#In total, 422 lesions (234 HCCs, 45 non-HCC malignancies, and 143 benign lesions) from 387 patients (79% male; mean age, 59 years) were included. In all lesions, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity and lower specificity than LR-5 (LI-RADS v2018) (87.2% [204/234] vs. 80.8% [189/234], p < 0.001; 86.2% [162/188] vs. 91.0% [171/188], p = 0.002). However, in lesions of size ≥ 2 cm, the definite HCC had a higher sensitivity than the LR-5 (86.8% [164/189] vs. 82.0 (155/189), p = 0.002) without a reduction in the specificity (80.0% [48/60] vs. 83.3% [50/60], p = 0.15).In all lesions, the sensitivity and specificity of the definite/probable HCC (2018 KLCA-NCC PG) and LR-5/4 did not differ significantly (89.7% [210/234] vs. 91.5% [214/234], p = 0.204; 83.5% [157/188] vs. 79.3% [149/188], p = 0.071). @*Conclusion@#For the diagnosis of HCC of size ≥ 2 cm, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity than LR-5, without a reduction in specificity. The definite/probable HCC (2018 KLCA-NCC PG) had a similar sensitivity and specificity to that those of the LR-5/4.

4.
Korean Journal of Radiology ; : 1066-1076, 2021.
Article in English | WPRIM | ID: wpr-894745

ABSTRACT

Objective@#To evaluate the performance of the 2018 Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) Practice Guidelines (hereafter, PG) for the diagnosis of hepatocellular carcinoma (HCC) using gadoxetic acid-enhanced MRI, compared to the Liver Imaging-Reporting and Data System (LI-RADS) version 2018 (hereafter, v2018). @*Materials and Methods@#From January 2013 to October 2015, treatment-naïve hepatic lesions (≥ 1 cm) on gadoxetic acidenhanced MRI in consecutive patients with chronic hepatitis B or cirrhosis were retrospectively evaluated. For each lesion, three radiologists independently analyzed the imaging features and classified the lesions into categories according to the 2018 KLCA-NCC PG and LI-RADS v2018. The imaging features and categories were determined by consensus. Generalized estimating equation (GEE) models were used to compare the per-lesion diagnostic performance of the 2018 KLCA-NCC PG and LI-RADS v2018 using the consensus data. @*Results@#In total, 422 lesions (234 HCCs, 45 non-HCC malignancies, and 143 benign lesions) from 387 patients (79% male; mean age, 59 years) were included. In all lesions, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity and lower specificity than LR-5 (LI-RADS v2018) (87.2% [204/234] vs. 80.8% [189/234], p < 0.001; 86.2% [162/188] vs. 91.0% [171/188], p = 0.002). However, in lesions of size ≥ 2 cm, the definite HCC had a higher sensitivity than the LR-5 (86.8% [164/189] vs. 82.0 (155/189), p = 0.002) without a reduction in the specificity (80.0% [48/60] vs. 83.3% [50/60], p = 0.15).In all lesions, the sensitivity and specificity of the definite/probable HCC (2018 KLCA-NCC PG) and LR-5/4 did not differ significantly (89.7% [210/234] vs. 91.5% [214/234], p = 0.204; 83.5% [157/188] vs. 79.3% [149/188], p = 0.071). @*Conclusion@#For the diagnosis of HCC of size ≥ 2 cm, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity than LR-5, without a reduction in specificity. The definite/probable HCC (2018 KLCA-NCC PG) had a similar sensitivity and specificity to that those of the LR-5/4.

5.
Ultrasonography ; : 121-129, 2020.
Article | WPRIM | ID: wpr-835314

ABSTRACT

Purpose@#The purpose of this study was to evaluate the intra-observer reproducibility of ultrasound attenuation imaging (ATI) for the noninvasive assessment of hepatic steatosis in patients with suspected hepatic steatosis and the inter-observer reproducibility in asymptomatic volunteers. @*Methods@#This prospective study was approved by our institutional review board and informed consent was obtained from all patients. In group 1, composed of patients with suspected hepatic steatosis (n=143), one abdominal radiologist performed gray-scale ultrasonography and two sessions of ATI. In group 2, composed of healthy volunteers (n=18), three independent sessions of ATI were performed by three abdominal radiologists. The visual degree of hepatic steatosis in all study subjects was graded on a 4-point scale by two independent reviewers using gray-scale ultrasonography. Thereafter, the attenuation coefficient (AC) was correlated with the degree of hepatic steatosis using Spearman rank correlation analysis. Intra-class correlation coefficients (ICCs) were used to assess the intra-observer (group 1) and inter-observer reproducibility (group 2) of ATI measurements. @*Results@#For the intra-observer reproducibility of ATI, the ICC was 0.929 (95% confidence interval [CI], 0.901 to 0.949), and the coefficient of variation was 7.1%. Inter-observer reproducibility of ATI measurements showed an ICC of 0.792 (95% CI, 0.549 to 0.916). The AC showed a significant correlation with the visual grade of hepatic steatosis for both reviewers (rho, 0.780 and 0.695; P<0.001, respectively). @*Conclusion@#ATI showed high intra- and inter-observer reproducibility in the assessment of hepatic steatosis.

6.
Journal of the Korean Radiological Society ; : 117-121, 2019.
Article in English | WPRIM | ID: wpr-916724

ABSTRACT

Intramural hematoma of the gastrointestinal tract is a rare disease entity. Pancreatitis-induced intramural gastric hematoma (IGH) is far more seldom reported. Here, we report a rare case of a giant IGH occurring as a delayed complication of pancreatitis in a 51-year-old man. The diagnosis was made using computed tomography (CT) and endoscopic ultrasonography. The patient was conservatively managed, and follow-up abdominal CT showed marked decreases in the size of the IGH.

7.
Ultrasonography ; : 345-354, 2019.
Article in English | WPRIM | ID: wpr-761991

ABSTRACT

PURPOSE: The purpose of this study was to compare the technical success rate and reliability of measurements made using three shear wave elastography (SWE) techniques and to assess the inter-platform reproducibility of the resultant liver stiffness measurements. METHODS: This prospective study included 54 patients with liver disease. Liver stiffness (LS) measurements were obtained using 2-point SWE techniques (Virtual Touch Quantification and S-Shearwave) and 2-dimensional (2D) SWE, with transient elastography (TE) serving as the reference standard. The technical success rates and measurement reliability of the three techniques were compared. LS values measured using the three SWE techniques and TE were compared using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Intra-class correlation coefficients (ICC) were used to analyze the inter-platform reproducibility of LS measurements. RESULTS: The three SWE techniques and TE showed similar technical success rates (P=0.682) but demonstrated significant differences in the reliability of LS measurements (P=0.006) and mean LS measurements (P<0.001). Despite strong correlations (r=0.73-0.94) between SWE systems, various degrees of inter-platform reproducibility (ICC, 0.58-0.92) were observed for the three SWE techniques. The best agreement was observed between S-Shearwave and TE (ICC, 0.92), and the worst agreement was observed between 2D-SWE and TE (ICC, 0.58). In the Bland-Altman analysis, a tendency toward lower LS values with the three SWE techniques than with TE in patients with F3 and F4 disease was observed. CONCLUSION: Significant inter-system variability was observed in LS measurements made using the three SWE techniques. Therefore, LS values measured using different SWE techniques should not be used interchangeably for longitudinal follow-up.


Subject(s)
Humans , Elasticity Imaging Techniques , Follow-Up Studies , Liver Cirrhosis , Liver Diseases , Liver , Prospective Studies
8.
Ultrasonography ; : 246-254, 2019.
Article in English | WPRIM | ID: wpr-761981

ABSTRACT

PURPOSE: The purpose of this study was to retrospectively compare the technical success and reliability of the measurements made using two 2-dimensional (2D) shear wave elastography (SWE) systems using the comb-push technique from the same manufacturer and to assess the intersystem reproducibility of the resultant liver stiffness (LS) measurements. METHODS: Ninety-four patients with suspected chronic liver diseases were included in this retrospective study. LS measurements were obtained using two 2D-SWE systems (LOGIQ E9 and LOGIQ S8) from the same manufacturer, with transient elastography (TE) serving as the reference standard, on the same day. The technical success rates and reliability of the measurements of the two 2D-SWE systems were compared. LS values measured using the two 2D-SWE systems and TE were correlated using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Thereafter, Bland-Altman limits of agreement and intraclass correlation coefficients (ICCs) were used to analyze the intersystem reproducibility of LS measurements. RESULTS: The two 2D-SWE systems showed similar technical success rates (98.9% for both) and reliability of LS measurements (92.3% for the LOGIQ E9, 91.2% for the LOGIQ S8; P=0.185). Despite the excellent correlation (ICC=0.92), the mean LS measurements obtained by the two 2D-SWE systems were significantly different (LOGIQ E9, 6.57±2.33 kPa; LOGIQ S8, 6.90±6.64 kPa; P=0.018). CONCLUSION: Significant intersystem variability was observed in the LS measurements made using the two 2D-SWE systems. Therefore, even 2D-SWE systems from the same manufacturer should not be used interchangeably in longitudinal follow-up.


Subject(s)
Humans , Elasticity Imaging Techniques , Follow-Up Studies , Liver Cirrhosis , Liver Diseases , Liver , Reproducibility of Results , Retrospective Studies , Ultrasonography
9.
Korean Journal of Radiology ; : 930-937, 2018.
Article in English | WPRIM | ID: wpr-717855

ABSTRACT

OBJECTIVE: The purpose of this study was to asses the CT findings and clinical features differentiating malignant from benign focal splenic lesions. MATERIALS AND METHODS: Among 673 patients with splenectomy, we included 114 patients with pathologically confirmed focal splenic lesions (malignant = 66, benign = 48). Two radiologists retrospectively assessed CT findings including: size, number, solid component, margin, wall, calcification, contrast-enhancement, lymph node (LN) enlargement and possible malignancy. We assessed clinical features including age, sex, underlying malignancy, fever, and leukocytosis. Multivariate logistic regression analysis was performed to identify significant predictors of malignant lesion. We used receiver operating curve analysis for determination of diagnostic performance. RESULTS: Common findings of malignant lesions include enhanced, mainly solid, ill-defined margin, absence of splenomegaly, absence of the wall, absence of calcification, LN enlargement, and presence of underlying malignancy (p < 0.05). Among them, mainly solid features (odds ratio [OR], 39.098, p = 0.007), LN enlargement (OR, 6.326, p = 0.005), and presence of underlying malignancy (OR, 8.615, p = 0.001) were significant predictors of malignancy. The mean size of benign splenic lesions (5.8 ± 3.3 cm) was larger than that of malignant splenic lesions (4.0 ± 3.4 cm). Diagnostic performance of CT findings by two reviewers using receiver operating characteristic curve analysis for differentiation of malignant lesions was 0.856 and 0.893, respectively. CONCLUSION: Solid nature of the splenic mass on CT images, LN enlargement, and presence of underlying malignancy are significant predictors of malignant splenic lesion.


Subject(s)
Humans , Equidae , Fever , Leukocytosis , Logistic Models , Lymph Nodes , Retrospective Studies , ROC Curve , Spleen , Splenectomy , Splenic Diseases , Splenomegaly
10.
Korean Journal of Radiology ; : 926-935, 2017.
Article in English | WPRIM | ID: wpr-191313

ABSTRACT

OBJECTIVE: To assess intra- and inter-observer reproducibility of a new point shear wave elastography technique (pSWE, S-Shearwave, Samsung Medison) and compare its accuracy in assessing liver stiffness (LS) with an established pSWE technique (Virtual Touch Quantification, VTQ). MATERIALS AND METHODS: Thirty-three patients were enrolled in this Institutional Review Board-approved prospective study. LS values were measured by VTQ on an Acuson S2000 system (Siemens Healthineer) and S-Shearwave on an RS-80A (Samsung Medison) in the same session, followed by two further S-Shearwave sessions for inter- and intra-observer variation at 8-hour intervals. The technical success rate (SR) and reliability of the measurements of both pSWE techniques were compared. The intra- and inter-observer reproducibility of S-Shearwave was determined by intraclass correlation coefficients (ICCs). LS values were measured by both methods of pSWE. The diagnostic performance in severe fibrosis (F ≥ 3) and cirrhosis (F = 4) was evaluated using the receiver operating characteristics curve analysis and the Obuchowski measure with the LS values of transient elastography as the referenced standard. RESULTS: The VTQ (100%, 33/33) and S-Shearwave (96.9%, 32/33) techniques did not display a significant difference in technical SR (p = 0.63) or reliability of LS measurements (96.9%, 32/33; 93.9%, 30/32, respectively, p = 0.61). The inter- and intra-observer agreement for LS measurements using the S-Shearwave technique was excellent (ICC = 0.98 and 0.99, respectively). The mean LS values of both pSWE techniques were not significantly different and exhibited a good correlation (r = 0.78). To detect F ≥ 3 and F = 4, VTQ and S-Shearwave showed comparable diagnostic accuracy as indicated by the following outcomes: areas under receiver operating characteristics curve (AUROC) = 0.87 (95% confidence intervals [CI] 0.70–0.96), 0.89 for VTQ (95% CI 0.74–0.97), respectively; and AUROC = 0.84 (95% CI 0.67–0.94), 0.94 (95% CI 0.80–0.99) for S-Shearwave (p > 0.48), respectively. The Obuchowski measures were similarly high for S-Shearwave and VTQ (0.94 vs. 0.95). CONCLUSION: S-Shearwave shows excellent inter- and intra-observer agreement and diagnostic effectiveness comparable to VTQ in detecting LS.


Subject(s)
Humans , Elasticity Imaging Techniques , Fibrosis , Liver Cirrhosis , Liver Diseases , Liver , Observer Variation , Prospective Studies , ROC Curve
SELECTION OF CITATIONS
SEARCH DETAIL